Fireye Direct Replacement Upgrades
|
We only sell new, factory fresh, FM approved items. Would you
risk your plant or building on a "rebuilt or reconditioned" item?
|
800-876-0036
Phone: 847-356-0566 Fax: 847-356-0747 E-Mail:
sales@mmcontrol.com
|
Direct Replacement Upgrades |
No wiring changes necessary (see notes). Use existing wiring base and flame scanner.
C-Series to D-Series or E110 Flame-Monitor |
C-Series Model |
D-Series |
Flame-Monitor |
25CU6-5065 |
70D10, 71D60
72DUV1 |
E110, ED510,
EP160, EUV1 |
25CU6-5066 |
70D20, 71D60
72DUV1 |
E110, ED510,
EP260, EUV1 |
25CF6-5022 |
70D10, 71D60
72D1R1 |
E110, ED510,
EP160, E1R1 |
25CF6-5023 |
70D20, 71D60
72D1R1 |
E110, ED510,
EP260, E1R1 |
25CU6-5062 |
70D30, 71D80
72DUV1 |
E110, ED510,
EP380, EUV1 |
25CU6-5063 |
70D30, 71D90
72DUV1 |
E110, ED510,
EP390, EUV1 |
25CF6-5020 |
70D30, 71D80
72D1R1 |
E110, ED510,
EP380, E1R1 |
25CF6-5021 |
70D30, 71D90
72D1R1 |
E110, ED510,
EP390, E1R1 |
25CJ5-5010 |
70D30, 71D80
72DRT1 |
E110, ED510,
EP380, ERT1 |
25CJ5-5011 |
70D30, 71D90
72DRT1 |
E110, ED510,
EP390, ERT1 |
|
|
Notes:
L1-13, 13-3 circuits: Some C-Series and D-Series controls were installed on a burner that did not have a fuel valve end switch terminal (13 – 3) and the operating control was wired between L1 and 3. When upgrading to a Flame-Monitor on these installations, after verifying a fuel valve end switch is not installed (e.g., no wire on terminal 13), jumper terminal 13 to 3. |
Early Spark Termination (Terminal X): On the non-modulating C-Series and D-Series (70D30) controls, terminal X would provide a 5 second pilot trial for ignition (PTFI). If terminal X is required, terminal 5 must be jumpered to terminal 10 when using the EP380, EP381, or EP390 programmers. |
|
 |
CAUTION: Refer to Bulletin E-1101 for proper installation, grounding, operational and safety checkout procedures. Perform safety checks of the entire system prior to allowing fuel entry to boiler. |
|
D-Series Chassis and
Programmer |
E-Series
Programmer |
All Flame-Monitor controls
require an E110 chassis
and ED510 display module. |
70D10 and 71D60 |
EP160 |
70D10 and 71D61 |
EP161 |
70D10 and 71D70 |
EP170 |
70D20 and 71D60 |
EP260 |
70D20 and 71D61 |
EP261 |
70D20 and 71D70 |
EP270 |
70D30 and 71D80 |
EP380 |
70D30 and 71D81 |
EP381 |
70D30 and 71D90 |
EP390 |
D-Series Amplifier |
E-Series Amplifier |
Use With Flame Scanners |
72DUV1 |
EUV1 |
UV1A, UV2, UV8A, UV90, 45UV3-1050 |
72D1R1 |
E1R1 |
48PT2 |
72DRT1 |
ERT1 * |
45CM1,69ND1 |
72DUVS4 |
EUVS4 |
45UV5-1007, -1008, -1009 |
|
|
* Ensure S2 is connected to earth ground when using ERT1 Fireye Primeline Products. |
|